Problem possible cause remedy
Logs are not being split properly
(insufficient splitting performance)
⇒ The log is not positioned correctly
⇒ The log exceeds the maximum dimen-
sions or the wood is too hard for the per-
formance of the machine
⇒ Splitting blade does not split log
⇒ Hydraulic pressure too low
⇒ Release rods bent (hydraulic tappet not
quite pressed in)
⇒ Incorrect connecting lead (longer than
10 m or too small cable cross-section)
⇒ Reposition the log correctly
⇒ Cut the log to the required dimen-
sions (page 19)
⇒ Sharpen splitting blade, check for
burrs or notches (page 22)
⇒ Check the oil level and add more oil
if necessary. (page 22)
If the problem cannot be rectified, re-
fer to the manufacturer or other ap-
proved service centre.
⇒ Arrange for manufacturer or author-
ised company to adjust the rods
⇒ Use the correct connecting lead
Log splitter does not operate, although the
motor is running
⇒ Valve does not open due to loose
connections
⇒ The operating levers or parts thereof are
bent.
⇒ Check and tighten the parts
⇒ Have bent parts repaired by the
manufacturer or a company desig-
nated by him
Motor starts, but splitting column is not
retracted
⇒ Wrong direction of rotation of motor
⇒ Check motor’s direction of rotation
and change (refer to page 19)
Motor doesn’t start
⇒ No electrical power
⇒ 2-phase mode in threephase motor
⇒ Connection cable defective
⇒ Electric motor defective
⇒ Switch defective (DS)
⇒ Switch or capacitor defective
⇒ Check the fuse.
⇒ Have fuse and lead checked by
qualified electrician.
⇒ Replace the connection cable or
have it checked by an electrician.
⇒ To correct the problem, refer to the
manufacturer or other approved
service centre.